优势库存(1016)集成电路(IC)(6)电源IC(1)半导体存储器(38)二极管(14)场效应管MOSFET(8)可控硅IGBT(13)单片机(4)电容器(28)电阻器(2)电源/稳压器(53)连接器/接插件(64)保险丝(8)普通电池/蓄电池/动力电池(48)变压器(2)变送器(119)继电器(36)放大器(16)电线电缆(22)光电子/光纤/激光(24)微特电机(11)显示屏/显示器件/配件(14)电子产品试验设备(2)电子产品制造设备(2)仪器/仪表(1799)防静电产品(2)五金/工具(200)其他未分类(350)
- 其他电源IC(1)
- 单向可控硅(晶闸管)(2)
- 双向可控硅(晶闸管)(3)
- 可控硅(晶闸管)模块(8)
开关(118)
传感器(1120)
- 光电/光敏传感器(14)
- 光学传感器(16)
- 电磁传感器(2)
- 霍尔传感器(3)
- 电流(压)传感器(19)
- 电导率传感器(1)
- 温(湿)度传感器(80)
- 声波/声敏传感器(3)
- 光纤/激光传感器(8)
- 测距/距离传感器(3)
- 视觉/图像传感器(15)
- 微波传感器(15)
- 压力传感器(192)
- 力敏传感器(1)
- 称重传感器(9)
- 测力/力矩/扭矩传感器(13)
- 速度传感器(4)
- 加速度传感器(10)
- 气体/气敏/烟雾传感器(446)
- 液位传感器(8)
- 物(料)位传感器(2)
- 振动/接近/位移传感器(85)
- 开关传感器(7)
- 流量传感器(43)
- 风速/风向/风量传感器(5)
- 角度/倾角传感器(10)
- 射线辐射传感器(1)
- 色标/颜色传感器(8)
- 火焰(警)传感器(18)
- 旋转传感器(3)
- 区域传感器(1)
- 汽车传感器(1)
- 陀螺仪(2)
- 真空度传感器(1)
- 其他传感器(70)
- 熔断保险丝(8)
变频器(78)逆变器(3)
- 正弦波逆变器(3)
- 红外线发射管(3)
- 光纤/光缆(3)
- 光纤交换机(7)
- 光纤连接器(1)
- 光电隔离/转换中继器(2)
- 光纤网卡(1)
- 激光器(1)
- 其他光电子、激光器件(6)
PLC/可编程控制器(74)编码器(50)安防监控器材(18)IT/电子产品成套件(86)电子测量仪器(569)
- 万用表/多用电表(43)
- 兆欧表(摇表)(1)
- LCR测试仪(9)
- 衰减器(19)
- 示波器(37)
- 数据采集仪(2)
- 集成电路测试仪(1)
- 漏电流测试仪(3)
- 信号发生器/信号源模块(4)
- 相位测试仪(3)
- 场强仪(2)
- 频率计/频率计数器(5)
- 功率计(4)
- 功率分析仪(7)
- 光功率计(36)
- 红外/遥控编码测试仪(2)
- 电声测试/分析仪(1)
- 亮度/照度计(2)
- 阻抗分析仪(13)
- 频谱分析仪(27)
- 网络分析仪(4)
- 网络测试仪(24)
- 矢量信号分析仪(3)
- 误码分析仪(1)
- 逻辑分析仪(2)
- 变压器/线圈测试仪(2)
- 表面/接地/绝缘电阻测试仪(21)
- 电子测量用工夹具(1)
- 综合测试/分析仪(15)
- 电磁兼容(EMC)测量仪器(8)
- 点温计(3)
- 测量探头及附(配)件(46)
- 其它电子测量仪器(218)
- 高温/低温/高低温试验设备(1)
- 温湿度试验设备(1)
- 其他设备(2)
电子材料(4)
- 其它电子原辅材料(4)
- 离子风机/风鼓(2)
相关产品
产品信息
TR-57DCi 红外数据读写器
【OverView】
The TR-57DCi is a Data Collector designed to collect recorded data from data loggers (T&D Thermo Recorders and Voltage Recorders).
It can be used to gather and check recorded data on the spot without having to manually gather the data loggers. Recording settings such as “ Recording Interval” and “Recording Start” can also be made directly from the TR-57DCi into the logger.
Compatible devices for use with the TR-57DCi include TR-5i Series (Infrared Communication Type), TR-5S/5 Series, RTR-500/5 Series, TR-7Ui/7U/7S Series, and VR-71 Data Loggers.
It can be used to gather and check recorded data on the spot without having to manually gather the data loggers. Recording settings such as “ Recording Interval” and “Recording Start” can also be made directly from the TR-57DCi into the logger.
Compatible devices for use with the TR-57DCi include TR-5i Series (Infrared Communication Type), TR-5S/5 Series, RTR-500/5 Series, TR-7Ui/7U/7S Series, and VR-71 Data Loggers.
【Communication Between TR-57DCi and Compatible Data Loggers】
The communication method will depend upon the type of Data Logger.
Infrared Communication:
By placing the infrared port of TR-57DCi Data Collector and TR-7Ui Series, TR-5i Series Data Loggers face-to-face, it is possible to download recorded data via infrared communication.
* Infrared communication cannot be used to make recording settings or send the "Recording Start" command.
Infrared Communication:
By placing the infrared port of TR-57DCi Data Collector and TR-7Ui Series, TR-5i Series Data Loggers face-to-face, it is possible to download recorded data via infrared communication.
* Infrared communication cannot be used to make recording settings or send the "Recording Start" command.
Optical Communication:
By using the optical communication interface of the TR-57DCi Data Collector, it is possible to collect recorded data from, make recording settings for, and start recording in TR-5i Series (Infrared Communication Type), TR-5S/5 Series, and RTR-5 Series Data Loggers.
By using the optical communication interface of the TR-57DCi Data Collector, it is possible to collect recorded data from, make recording settings for, and start recording in TR-5i Series (Infrared Communication Type), TR-5S/5 Series, and RTR-5 Series Data Loggers.
Cable Communication:
By connecting the cables shown below to the serial communication cable jack on the Data Collector, it is possible to collect data from and make settings for TR-7Ui /7U/7S Series and VR-71 Data Loggers.
* There are some items for the VR-71 which cannot be set via cable communication, such as switching the unit for the unit s LCD display.
By connecting the cables shown below to the serial communication cable jack on the Data Collector, it is possible to collect data from and make settings for TR-7Ui /7U/7S Series and VR-71 Data Loggers.
* There are some items for the VR-71 which cannot be set via cable communication, such as switching the unit for the unit s LCD display.
[Connection between PC and TR-57DCi]
The collected data can be easily downloaded from the TR-57DCi with a USB cable to a PC.
By using an optional RS-232C Serial Communication Cable (TR-07C), it is also possible to communicate with a PC via serial communication.
[Easy Data Collection on the Spot: No Computer Necessary]
The TR-57DCi enables you to not only easily collect recorded data from Data Loggers, but allows you to view the data as a Graph; all without a PC. The collection of data can be carried out using any of three communication methods: Optical communication by placing the Logger on top of the TR-57DCi, connect to the Logger using the provided cable or by using the newly added Infrared Communication.
Compatible Devices:
TR-71Ui/72Ui/73U/74Ui/76Ui/77Ui, TR-71U/72U, TR-71S/72S, TR-51i/52i/55i, TR-51S/52S, TR-51/51A/52, VR-71,
* RTR-51(L)/52(L)/52Pt(L)/53(L)/51A(L)/52A(L)/53A(L), RVR-52(L)/52A(L), RTR-501/502/503/574
* The TR-57DCi is not equipped with a wireless communication function.
[Large Storage Capacity: Up to 256,000 Readings]
One TR-57DCi has the capacity to store 16 units of TR-51i or TR-52i at full logging capacity. When downloading units at non-full logging capacity, it can collect and store up to 250 downloading sessions.
[Collect Recorded Data via Infrared Communication]
The TR-57DCi can also use infrared communication to collect recorded data from any of the TR-7Ui and TR-5i Series Data Loggers. Using infrared communication releases the user from the burden of physically gathering the loggers to collect data.
The TR-57DCi can also use infrared communication to collect recorded data from any of the TR-7Ui and TR-5i Series Data Loggers. Using infrared communication releases the user from the burden of physically gathering the loggers to collect data.
[Graph Display on High Quality LCD]
Collected data can be easily displayed in graph form on the LCD. A graph is displayed for each channel of data and can be scrolled left and right with the Operation Dial, making the checking of data a snap. It is also possible to zoom in and out with the buttons on the face of the Unit. Moreover, the accuracy of the data display has been greatly improved when compared to our previous TR-57U Data Collector. These factors make it possible to check the data on the spot wherever you may be recording data.
When there are two channels of recorded data, you can change the channel on the display by holding in the Operation Dial for about 1.5 seconds.
[Handy Operation Dial for a Variety of Operations]
Moving the Operation Dial up and down displays the various menu selections which can be easily selected by pressing in on the dial.
Moving the Operation Dial up and down displays the various menu selections which can be easily selected by pressing in on the dial.
Moving the Dial Up and Down
- By moving the dial up and down, the arrow will move to allow you to choose the desired item.
- When setting a numerical value, by moving the dial up the value will become larger, and by moving the dial down the value will become smaller.
Pressing the Operation Dial
- By pushing in on the dial, you can make a desired menu selection and complete or activate a setting.
- If you press and hold while downloading recorded data or viewing a graph display, you can change the channel on display.
[Easy-to-Make Recording Condition Settings]
From the TR-57DCi, it is possible to make settings for "Recording Start Date and Time","Recording Interval", and "Recording Mode" for all compatible data loggers.
NOTE: Settings for the VR-71, such as the input voltage range setting, cannot be made from the TR-57DCi.
[Battery Life Warning Display]
When battery life goes low, a battery life warning mark will be displayed to inform you it is time to replace the battery. If battery life goes even lower, the Unit will automatically go into sleep mode in order to save data.
NOTE:
- In sleep mode, the Unit cannot be turned on or operated as usual.
- When replacing the battery, if the battery has been removed for more than five minutes, the data stored in the Unit may be erased. It is recommended to first download any necessary recorded data to your computer before replacing the battery.
- Also, you will lose all data if the battery drains completely; make sure to replace the battery as soon as possible.
[About 100 Days of Battery Life on One Hour Daily Use]
The expected battery life for two AAA alkaline batteries (LR03) is about 100 days if used one hour daily. In addition to AAA alkaline batteries, AAA Ni-Cd or AAA Ni-MH batteries (1.2V) may also be used.
NOTE: Battery life varies depending upon the type of battery, the measuring environment, the frequency of communication, and the ambient temperature in which it is used. Specifications and explanations used in this User s Manual are based on operations carried out with a new battery and are in no way a guarantee of your actual battery life.
[Auto Power OFF Function: No Battery Drain]
If the Unit is not used for about three minutes, it will automatically turn off to save battery power.
[LCD Backlight Display: Read Data even in the Dark]
The LCD Backlight allows the display to be easily read even in the dark. You can make changes to the Backlight ON/OFF setting by going to the [Main] Menu - [Set Functions] - [Set Backlight].
NOTE: If the Unit is not used for more than five seconds, the LCD Backlight will automatically turn off to save battery power. Once operation is re-started, it will automatically turn back ON.
[Firmware Update Function]
The firmware can be easily updated by connecting the target TR-57DCi with a USB communication cable to the computer. As newly compatible devices are released, firmware updates will be periodically released to support these changes.
[Specifications]
TR-57DCi | |
Compatible Devices |
Infrared Communication: TR-51i/52i/55i, TR-71Ui/72Ui/74Ui/76Ui/77Ui Cable Communication: TR-71U/72U/73U/74Ui/76Ui/77Ui, TR-71S/72S, RTR-574, VR-71 Optical Communication: TR-51i/52i/55i, TR-51S/52S, TR-51A/52, RTR-51(L)/51A(L)/52(L)/52A(L)/52Pt(L)/53(L)/53A(L)/501/502/503, RVR-52(L)/52A(L) |
Storage Capacity |
Up to 256,000 readings When downloading units at full logging capacity: 16 units of TR-51i 16 units of TR-71U 10 units of TR-73U, TR-76Ui 7 units of TR-74Ui When downloading units at non-full logging capacity, it can store and manage up to 250 downloading sessions. |
Functions | Downloading Recorded Data, Viewing Saved Data in Graph Form, Recording Start Settings, Displaying Highest and Lowest Measurement |
Power |
AAA Alkaline Battery (LR03) x 2 (AAA Ni-Cd batteries or AAA Ni-MH batteries (1.2V) may also be used.) AC Adaptor (optional) |
Battery Life(*1) | About 100 days at 1 hour of daily use |
Communication Interfaces (with PC) |
USB Communication RS-232C Communication: 19,200 bps |
Communication Interfaces (with Data Logger) |
RS-232C Communication: 9,600 to 19,200 bps Optical Communication: 2,400 bps Infrared Communication) |
Communication Time |
?Between PC and TR-57DCi Data Collector USB Communication (16,000 readings x 1ch): about 12 sec. USB Communication (8,000 readings x 4ch): about 24 sec. RS-232C Communication (16,000 readings x 1ch): about 22 sec. RS-232C Communication (8,000 readings x 4ch): about 42 sec. ?TR-5i Series Data Logger Optical Communication (16,000 readings x 1ch): about 24 sec. Infrared Communication (16,000 readings x 1ch): about 55 sec. ?TR-7Ui Series Data Logger Infrared Communication (8,000 readings x 2ch): about 55 sec. Infrared Communication (8,000 readings x 4ch): about 77 sec. ?TR-5S Series Data Logger Optical Communication (16,000 readings x 1ch): about 24 sec. |
Dimensions | H125mm x W58mm x D23.8mm (excluding protrusions) |
Weight | About 110g (including 2 AAA batteries) |
Operating Environment | Temperature: 0 to 60°C Humidity: 90%RH or less (no condensation) |
*1) Battery life varies depending upon the type of battery, the measuring environment, the frequency of communication, and the ambient temperature in which it is used.
[Dimensions]
1. Operation Dial
2. LCD Display
3. Operation Buttons
4. Optical Communication Port
5. USB Communication Cable Jack
6. RS-232C Communication Cable Jack
7. AC Adaptor Jack
8. Infrared Communication Port
9. Battery Cover