上海艾斯达电子

18年

上海艾斯达电子

卖家积分:28001分-29000分营业执照:已审核经营模式:经销商所在地区:上海 上海市企业网站:
http://WWW.ASDDZ.COM

收藏本公司 人气:2592286

企业档案

  • 相关证件:营业执照已审核 
  • 会员类型:
  • 会员年限:18年
  • 钱先生,张小姐 QQ:345952988
  • 电话:021-51035787
  • 手机:13764678882
  • 韩小姐 QQ:809867380
  • 阿库IM:
  • 地址:上海北京东路668号赛格电子市场G537室
  • 传真:021-51571116
  • E-mail:isd99@163.com

产品分类

优势库存(1016)集成电路(IC)(6)电源IC(1)半导体存储器(38)二极管(14)场效应管MOSFET(8)可控硅IGBT(13)单片机(4)电容器(28)电阻器(2)电源/稳压器(53)连接器/接插件(64)开关(118)传感器(1120)保险丝(8)普通电池/蓄电池/动力电池(48)变压器(2)变送器(119)继电器(36)变频器(78)逆变器(3)放大器(16)电线电缆(22)光电子/光纤/激光(24)微特电机(11)显示屏/显示器件/配件(14)PLC/可编程控制器(74)编码器(50)安防监控器材(18)IT/电子产品成套件(86)电子测量仪器(569)电子产品试验设备(2)电子产品制造设备(2)仪器/仪表(1799)电子材料(4)防静电产品(2)五金/工具(200)其他未分类(350)
您的当前位置:上海艾斯达电子 > 元器件产品
供应日本横河高电压差分探头 701926,1000:1或100:1高电压(7kV峰值)探头
供应日本横河高电压差分探头 701926,1000:1或100:1高电压(7kV峰值)探头
<>

供应日本横河高电压差分探头 701926,1000:1或100:1高电压(7kV峰值)探头

型号/规格:

高电压差分探头 701926

品牌/商标:

YOKOGAWA(横河)

电压:

7KV

价格:

16300.0

产品信息

701926是1000:1或100:1高电压(7kV峰值)探头,带宽为DC~50MHz,该探头提供平衡的差分输入,可与单端输入的示波器一起使用。可以使用电池供电,或所有Yokogawa示波器中的探头供电端口进行操作。 差分探头由下列部件和附件组成。 配置 标准部件 1.探头 2.高电压鳄鱼夹(一套两个) 3.接地延长线(长度:约100cm) 4.功率电缆*(长度:约150cm) *电源可由DL系列700938或701934提供 探头部件名称 sm User's Manual Safety Precautions Make sure to observe the following safety precautions when handling the probe. Yokogawa Electric Corporation assumes no liability for the customer’s failure to comply with these safety precautions. Before you use the probe, read the measuring instrument’s manual to fully aware of its specifications and handling. The following symbols are used on this instrument. Warning: handle with care. Refer to the user’s manual or service manual. This symbol appears on dangerous locations on the instrument which require special instructions for proper handling or use. The same symbol appears in the corresponding place in the manual to identify those instructions. Risk of electric shock Make sure to observe the following safety precautions to prevent electric shock, personal injury, or damage to the instrument. WARNING Ground the measuring instrument Make sure to connect the protective grounding terminal of the measuring instrument to ground. Connect the probe earth cable Connect the probe earth cable to ground (grounding potential). Stop use if you suspect damage If you suspect that the probe is broken, consult your nearest YOKOGAWA dealer. Observe the maximum input voltage Do not apply voltage exceeding 7000 Vpeak between an input lead and ground or between two input leads. The maximum input voltage is 7000 Vpeak regardless of whether 1000:1 or 100:1 attenuation is used. Ground the probe Ground the probe by connecting the grounding conductor of the measuring instrument’s power cable or another appropriate grounding conductor to the BNC shell and an auxiliary grounding terminal. Before connecting the probe input terminal to the circuit under measurement, ensure that the measuring instrument is grounded properly, that the probe output connector is attached to the BNC connector of the measuring instrument, and that the auxiliary grounding terminal is connected to a proper ground. Do not remove the alligator clip’s cover To prevent electric shock or fire, do not remove the alligator clip’s insulation cover. Do not use in damp places To prevent electric shock, do not use the probe in damp places. Do not use in an explosive atmosphere To prevent fire and injury, do not use the probe in a flammable or explosive atmosphere or near steam. Do not touch exposed circuitry To prevent injury, remove metallic objects and jewelry such as rings and watches. Do not touch exposed live connections or components. CAUTION Use the correct power supply Power the probe by using four AA dry cells, by using a 6 VDC/200 mA or 9 VDC/150 mA external power supply, or by connecting a probe power cable to the DL Series probe power supply terminal, the 700938, or the 701934. Operating the probe while using a power supply exceeding the specified voltage may cause damage to the instrument. Turn OFF the probe when connecting an external power supply Turn the probe power switch OFF when connecting or disconnecting from the external power supply. Do not install AA batteries when using an external power supply. The following symbols are used in this manual. Improper handling or use can lead to injury to the user or damage to the instrument. This symbol appears on the instrument to indicate that the user must refer to the user’s manual for special instructions. The same symbol appears in the corresponding place in the user’s manual to identify those instructions. In the manual, the symbol is used in conjunction with the word “WARNING” or “CAUTION.” WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user, and precautions that can be taken to prevent such occurrences. CAUTION Calls attention to actions or conditions that could cause light injury to the user or damage to the instrument or the user’s data, and precautions that can be taken to prevent such occurrences. Note Calls attention to information that is important for proper operation of the instrument. Operating environment limitations See below for operating environment limitations. CAUTION This product is a Class A (for industrial environments) product. Operation of this product in a residential area may cause radio interference in which case the user will be required to correct the interference. Thank you for purchasing the High Voltage Differential Probe (701926) for the DL Series. To ensure correct use, please read this manual thoroughly before beginning operation. After reading this manual, keep it in a safe place. IM 701926-01E IM 701926-01E 1/2 Directive 2002/96/EC (This directive is only valid in the EU.) This product complies with the WEEE Directive (2002/96/EC) marking requirement. This marking indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category With reference to the equipment types in the WEEE directive Annex 1, this product is classified as a “Monitoring and Control instrumentation” product. Do not dispose in domestic household waste. When disposing products in the EU, contact your local Yokogawa Europe B. V. office. 1. Description This probe provides differential inputs to be used with oscilloscopes with single-ended inputs. 2. Configuration The differential probe consists of the following parts and accessories. Approx. 50 cm Approx. 90 cm 1 4 2 3 Standard parts Accessories sold separay 1. Probe Black high voltage alligator clip B8099RC 2. High voltage alligator clip (Two in a set) Red high voltage alligator clip B8099RD 3. Ground extension lead (length: approx. 100 cm) Power cable B9852MJ 4. Power cable* (length: approx. 150 cm) * Power can be supplied from the DL Series, 700938, or 701934. 3. Probe Part Names ADJUST (DC offset adjustment) Power LED Power switch BNC output connector Attenuation ratio selector 4. Installing or Replacing Batteries Slide the lid on the back side of the probe, and install or replace the four AA dry cells. The probe is shipped from the factory without the batteries installed. 5. Procedure 1. Connect the provided high voltage alligator clips to the probe input leads. 2. Supply power to the probe by one of the following methods. • Install four AA cells. The power LED blinks if the battery level goes low. If this message appears, replace the dry cells. • Connect the appropriate power cable to an external power supply. • Connect the probe power cable to a probe power supply terminal on the DL Series, the 700938, or the 701934. 3. Connect the BNC output connector to the oscilloscope input terminal, and properly ground the auxiliary ground terminal. If necessary, use the auxiliary ground extension lead. 4. Turn the power switch ON, and warm up the probe for at least 30 minutes. 5. Select the appropriate attenuation using the attenuation ratio selector. • For higher resolution and less noise when measuring signals less than or equal to 700 V, switch the attenuation to 1/100. • When measuring signals greater than 700 V, set the attenuation to 1/1000. 6. If the offset voltage is large, short the alligator clips, and turn the ADJUST variable resistor (DC voltage adjustment) using an appropriate flat-head screwdriver to adjust the offset voltage. 7. Connect the two probe input leads to the two points of measurement (differential measurement). The performance declines if you only connect a probe input lead to a single point. Make sure to connect both leads.