美国GE二氧化碳传感器模块T6615 CO2 Module
Compact CO2 Module Designed to Integrate Into Existing Controls and Equipment
The Telaire T6615 dual-channel CO2 Module is designed to meet the volume, cost, and delivery expectations of Original Equipment Manufacturers (OEMs). The T6615 is a dual channel sensor. The two channels can be described as a CO2 channel that measures gas concentration and a reference channel that measures the sensor signal intensity.
美国GE二氧化碳传感器模块特点
Features
An affordable gas sensing solution for OEMs.
A reliable sensor design based on 15 years of engineering and manufacturing expertise.
Flexible CO2 sensor platform designed to interact with other microprocessor devices.
Dual-channel optical system and three-point calibration process for enhanced stability, accuracy and reliability.
Designed for applications where ABC Logic cannot be used.
Applications
When used in a building monitoring system, the T6615 dual sensor module allows building owners and managers to quickly,easily and efficiently moniotr the building air quality to stay within regulation.
Specifications
Method Method Dual-channel Non Dispersive Infrared (NDIR), gold plated optics, diffusion or flow through sampling.
Measurement Range 0 to 2000 ppm
0 to 5000 ppm
0 to 10,000 ppm
0 to 50,000 ppm
Dimensions 2.25 in X 1.365 in X 0.60 in
(57.15 mm X 34.67 mm X 15.24 mm)
Accuracy* 75 ppm or 10% of reading (whichever is greater)
Temperature Dependence 0.2% FS per °C
Stability over Life of Sensor (10 Years) < 5% of FS or <10% reading annual
Pressure Dependence 0.135% of reading per mm Hg
Response Time < 2 minutes for 90% step change typical
Warm Up Time < 2 minutes (operational)
10 minutes (maximum accuracy)
Operating Conditions 32°F to 122°F (0°C to 50°C)
0 to 95% RH, non condensing
Storage Conditions -40°F to 158°F (-40°C to 60°C)
(Non Condensating)