- 非IC关键词
上海艾斯达电子
- 卖家积分:营业执照:已审核经营模式:经销商所在地区:上海 上海市企业网站:
http://WWW.ASDDZ.COM
收藏本公司 人气:2582760
企业档案
- 相关证件: 
- 会员类型:
- 会员年限:18年
- 阿库IM:
- 地址:上海北京东路668号赛格电子市场G537室
- 传真:021-51571116
- E-mail:isd99@163.com
产品分类
- 其他电源IC(1)
- 单向可控硅(晶闸管)(2)
- 双向可控硅(晶闸管)(3)
- 可控硅(晶闸管)模块(8)
- 光电/光敏传感器(14)
- 光学传感器(16)
- 电磁传感器(2)
- 霍尔传感器(3)
- 电流(压)传感器(19)
- 电导率传感器(1)
- 温(湿)度传感器(80)
- 声波/声敏传感器(3)
- 光纤/激光传感器(8)
- 测距/距离传感器(3)
- 视觉/图像传感器(15)
- 微波传感器(15)
- 压力传感器(192)
- 力敏传感器(1)
- 称重传感器(9)
- 测力/力矩/扭矩传感器(13)
- 速度传感器(4)
- 加速度传感器(10)
- 气体/气敏/烟雾传感器(446)
- 液位传感器(8)
- 物(料)位传感器(2)
- 振动/接近/位移传感器(85)
- 开关传感器(7)
- 流量传感器(43)
- 风速/风向/风量传感器(5)
- 角度/倾角传感器(10)
- 射线辐射传感器(1)
- 色标/颜色传感器(8)
- 火焰(警)传感器(18)
- 旋转传感器(3)
- 区域传感器(1)
- 汽车传感器(1)
- 陀螺仪(2)
- 真空度传感器(1)
- 其他传感器(70)
- 熔断保险丝(8)
- 正弦波逆变器(3)
- 红外线发射管(3)
- 光纤/光缆(3)
- 光纤交换机(7)
- 光纤连接器(1)
- 光电隔离/转换中继器(2)
- 光纤网卡(1)
- 激光器(1)
- 其他光电子、激光器件(6)
- 万用表/多用电表(43)
- 兆欧表(摇表)(1)
- LCR测试仪(9)
- 衰减器(19)
- 示波器(37)
- 数据采集仪(2)
- 集成电路测试仪(1)
- 漏电流测试仪(3)
- 信号发生器/信号源模块(4)
- 相位测试仪(3)
- 场强仪(2)
- 频率计/频率计数器(5)
- 功率计(4)
- 功率分析仪(7)
- 光功率计(36)
- 红外/遥控编码测试仪(2)
- 电声测试/分析仪(1)
- 亮度/照度计(2)
- 阻抗分析仪(13)
- 频谱分析仪(27)
- 网络分析仪(4)
- 网络测试仪(24)
- 矢量信号分析仪(3)
- 误码分析仪(1)
- 逻辑分析仪(2)
- 变压器/线圈测试仪(2)
- 表面/接地/绝缘电阻测试仪(21)
- 电子测量用工夹具(1)
- 综合测试/分析仪(15)
- 电磁兼容(EMC)测量仪器(8)
- 点温计(3)
- 测量探头及附(配)件(46)
- 其它电子测量仪器(218)
- 高温/低温/高低温试验设备(1)
- 温湿度试验设备(1)
- 其他设备(2)
- 其它电子原辅材料(4)
- 离子风机/风鼓(2)
产品信息
- Complete phase-sequence and motor-rotation testing in one instrument
- Ensures correct phase hookup in one easy test
- Rugged and portable tester
- Performs additional polarity and continuity checks
Motor and Phase Rotation Tester permits the electrical contractor or industrial maintenance electrician to permanently connect and tape the terminals of the motor being installed, without having to first energize the motor by a temporary hookup from a power source, if available, to determine motor rotation. Therefore, the test set eliminates the need for temporary connections that can be time consuming, costly and quite hazardous, particularly where many large, high-voltage motors are involved
Also, certain types of drives should never be rotated in the wrong direction. In such cases, the temporary hookup or trial method, having a fifty-fifty chance of being wrong, can do serious harm.
The three motor leads on the left side of the test set are for attachment to the terminals of the motor being tested for rotation determination. Fuses are inserted in the motor A and C test leads as protection in the event the user accidentally touches these leads to an energized circuit. These standard fuses are easily removed and replaced from their panel-mounted holders.
The three lines leading to the right of the test set are for direct attachment to energized ac power systems up to 600 volts to determine the system phase sequence .A four-position switch selects the test to be made —system phase sequence, motor rotation and transformer polarity. The selector switch connects a D-size dry cell into the circuit when the rotation of a motor or the polarity of a transformer is being checked. In the OFF position, both the meter and the battery are disconnected from all circuits.
A push switch is connected in series with the battery and opens the circuit during transformer polarity testing. The dry cell is easily removed and replaced from its panel-mounted holder by a coin-slot access cap. The DC zero-center ammeter indicates correct or incorrect rotation or polarity by deflecting its pointer to the right or left. A zero or null adjuster is provided for the ammeter
Included Accessories | |||
|